Guangdong Fullde Electrical Technology Co., Ltd

Guangdong Fullde Electrical Technology Co., Ltd

Manufacturer from China
Active Member
8 Years
Home / Products / Neutral Grounding Resistor /

10.5KV 48A Ner Neutral Earth Resistor / High Power Resistor Built - In Heater

Contact Now
Guangdong Fullde Electrical Technology Co., Ltd
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MissAlina
Contact Now

10.5KV 48A Ner Neutral Earth Resistor / High Power Resistor Built - In Heater

Ask Latest Price
Video Channel
Brand Name :Fullde
Model Number :FNGR-10.5KV-48A-120Ω-10S-20
Certification :CE, ISO9001
Place of Origin :Dongguan,China
MOQ :one set
Price :Negotiable
Payment Terms :L/C, D/A, D/P, Western Union, MoneyGram, T/T
Supply Ability :100 Sets per Month
Delivery Time :20 working days
Packaging Details :Wooden packaging,Carton packaging
Rated voltage :10.5KV
Rated resistance :120Ω±5%
Rated frequency :50Hz/60Hz
Weight :350KG
Dimension :900*1300*1650
Fault current :48A
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

10.5KV 48A Generator Neutral Grounding Resistance Complete Sets of Equipment

Brief introduction:

Neutral-Grounding Resistors (NGRs) are used to ground power systems by inserting a resistor between the system neutral and ground. This lowers the prospective ground-fault current to a predetermined value.
A properly designed resistance-grounded system provides benefits over both ungrounded and solidly grounded systems. Because the system is grounded, transient overvoltages do not occur and groundfault current can flow, allowing it to be detected and measured. Also,because a resistor is used to ground the system, the very large and destructive ground-fault currents of solidly grounded systems are absent. Ground-fault relays can be used on feeders to provide selective coordination and the ability to quickly locate or isolate the fault.

Applications:


Resistance grounding is typically applied on transformers and generators where safety and continuity of service are important. A faulted feeder may remain in operation until it is safe to repair the fault, where allowed by the local electrical code.

10.5KV-(50A-1300A)Neutral Ground Selection Table:

Fault

Current

Resistance

Malfunction

Time

Protection

Grade

Maximum

Temperature Rise

Box Material

Quality Selection

Optional
50A 60.62Ω 10s 43 760℃

1,stainless steel

2,Galvanized sheet

3,Ordinary steel plate

1,transformer

2, cable box

3, air switch

4, intelligent monitor

5, vacuum contactor

6, current transformer

10.5KV 48A Ner Neutral Earth Resistor / High Power Resistor Built - In Heater